Non contact infrared thermometer how to change to fahrenheit

Yes, the Geratherm® non Contact can be switched between Celsius and Fahrenheit.
To change the display from C to F, switch off the thermometer and press the START button for 5 seconds, after these 5 seconds the current measurement scale ( C or F symbol) lights up on the display.

Now switch the measurement scale between °C and °F by pressing the START button. Once you have selected the scale you want, wait 5 seconds for the thermometer to automatically switch to "Ready" mode for measurement.

Yes, the battery of the Geratherm® non Contact can be changed.
Caution: Keep the thermometer and batteries away from small children. If the battery is swallowed, contact a hospital immediately. Do not throw the battery into fire, it may explode.

No, the Geratherm® non Contact is a non-contact thermometer.
The thermometer measures the infrared energy emitted by the skin of the forehead. This energy is captured by lenses and converted into temperature readings. Temperature readings measured by scanning the area above the eyebrow are the most accurate.

Use a sponge soaked in alcohol or a cotton cloth dampened with alcohol (e.g. 70% isopropanol) to clean the thermometer housing and the measuring sensor. No liquid should get inside the thermometer. Don't use aggressive ones Detergents, solvents or benzene for cleaning and never immerse the device in water or other cleaning liquids.

The Geratherm® non Contact is not waterproof.

The Geratherm® non Contact complies with IP 22 and is therefore protected against solid foreign objects with a diameter of 12.5 mm and more and against water dripping at an angle of up to 15 degrees.

Observe the correct application according to the instructions for use. Measure again while observing the maximum distance to the forehead of 2 cm.
If the value is low again, carry out a control measurement with a conventional clinical thermometer.

For newborns under 6 months, carry out a control measurement with a conventional clinical thermometer.
A control measurement should also be carried out in children under three years of age with a weak immune system, in which the presence or absence of fever is decisive.

Berrcom JXB-178 Non-Contact Infrared Thermometer Quick Start Guide

USING THE THERMOMETER

Non contact infrared thermometer how to change to fahrenheit

IMPORTANT: BEFORE TAKING FIRST MEASUREMENT

The thermometer needs to acclimate to the ambient environment (temperature) in which measurements will occur. It is important to allow the JXB-178 to acclimate to the room temperature for at least 15 to 20 minutes prior to first using the thermometer.

Subsequent usage – each time there is a significant change in the ambient temperature due to a change in the environment, allow the JXB-178 to acclimate to this ambient temperature for at least 15 minutes prior to using it.

CHANGING TEMPERATURE MODE

While the thermometer is turned on, press the MODE button to toggle through the three temperature mode options: BODY, SURFACE or ROOM.

NOTE: When first using the thermometer, the default is set to BODY mode.

NOTE: Measurement ranges for each temperature mode are as follows:

BODY mode: 89.6°F to 109°F (32°C to 42.9°C)

SURFACE mode: 32°F to 140°F (0°C to 60°C)

ROOM mode: 50°F to 104°F (10°C to 40°C)

NOTE: Once the thermometer is powered on, the last temperature mode measured will default as the current temperature mode.

NOTE: Always use the BODY mode to measure internal human temperature.

CHANGING TEMPERATURE UNIT

While the thermometer is turned on, press the MODE button for 2 seconds, screen will display “F1”, then press the MODE button to transfer between degree Celsius and Fahrenheit, confirm by pressing the MEM button.

TAKING A MEASUREMENT

  1. Press ON/SCAN button to power on the thermometer. When the devise is ready, the LCD screen will turn green.
  2. Position the thermometer between 1.2″ to 2″ (3 to 5 cm) from the patient’s forehead.
  3. Press ON/SCAN button to take measurement.
  4. A measurement will be displayed on the LCD screen.
    • To repeat the process, return to step 2.
    • Allow 3 to 5 seconds between measurements.
  5. The thermometer automatically turns off after 30 seconds of inactivity.

Non contact infrared thermometer how to change to fahrenheit

Note: High temperature alarm default setting is 100.4˚F (38˚C).

LOW BATTERY DETECTION

If the battery voltage is not more than 2.7V, the JXB-178 Non-contact Infrared Thermometer will display the flashed symbol

Non contact infrared thermometer how to change to fahrenheit
to remind you to replace both batteries.

CHANGING THE BATTERIES

The JXB-178 Non-contact Infrared Thermometer requires 2 AA alkaline batteries. When the LCD screen displays

Non contact infrared thermometer how to change to fahrenheit
, both batteries should be replaced. Open the lid on the bottom of the thermometer and replace the batteries, noting the correct battery positioning. Wait 15-20 minutes for the unit to acclimate to the ambient environment (temperature) before performing a test.

TROUBLESHOOTING

Non contact infrared thermometer how to change to fahrenheit

Non contact infrared thermometer how to change to fahrenheit

Documents / Resources

How do you change C to F on non contact infrared thermometer?

How to change from F° to C°.
Firstly ensure the thermometer is turned on, you can do this by pressing the trigger (power button). ... .
Press and hold the 'Set' button until you see the screen flash 'F1' then 'Unit'.
In the top right corner, you will see either °F or °C flashing..